The I/O signals are located on the header pins as shown below Wx100-ModbusGW features 14 industrial voltage level digital and analog I/Os (see I/O specifications in Section 3) on a 20pin, 0.1″ pitch IDC header that can be read/written directly by the Modbus client.įor absolute lowest cost you can simply make a matching ribbon cable with a 0.1″ pitch IDC connector and tap the signals directly from the wires. If desired you can also cover up the unused I/O header pins using the silicone dust cover supplied with the product after installation of the Wx100-ModbusGW to protect the pins against accidental short circuiting. You only need to connect a regulated, 12 to 24V DC (maximum 30V) power supply to the +/- power supply terminals and a two-wire RS485 cable to the +/- terminal of RS485 connector, as shown below: If you are only using Wx100-ModbusGW as a gateway and not using its I/O function, then wiring is really simple. Please refer to Appendix A for detailed illustration on the various options for installing the Wx100-ModbusGW. It can also be installed readily on a DIN rail or using just screws, nuts and PCB standoffs. The Wx100-ModbusGW is flexible and can be installed on the front cover of any industrial enclosure. So the model name: “ Wx100-ModbusGW” throughout this document is applicable to either model. The only difference is whether the antenna is integrated inside the unit or can be installed externally. Note: Functionally, both Wx100-ModbusGW and Wx100-ExtA-ModbusGW are identical.

See Appendix A-3: Installing External Antenna for more details. This gateway model can be installed inside a metallic control panel since the Wi-Fi signal will be captured by the external antenna and conduct via the antenna cable into the CPU.


The antenna is integrated on the module itself. Wx100-ModbusGW: This is a standard model with an internal antenna for the WiFi signal.*Maximum range achieved in open field site at height of 3 metres (9. It is now amongst the most common available means for connecting industrial electronic devices. Over time its simple and robust nature has made it a communication protocol standard.
#WIRELESS MODBUS RTU GATEWAY SERIAL#
*Modbus is a serial communications protocol which was originally designed for use with PLCs (Programmable logic controllers).
#WIRELESS MODBUS RTU GATEWAY FREE#
The licence free 2.4 GHz direct sequence spread spectrum (DSSS) radio telemetry technology offers high integrity, error free communications which can co-exist with other wireless technologies such as Wi-Fi, Bluetooth® and Zigbee®. The wireless telemetry Modbus gateway offers some simple commands available to wake, sleep, and keep awake T24 transmitters.
#WIRELESS MODBUS RTU GATEWAY DOWNLOAD#
The T24-GW1 uses either the standard Modbus interface RTU* protocol or a simple ASCII protocol.Ĭlick here to view & download associated free software. The T24-GW1 is a wireless Modbus gateway that provides a simple interface for users to gather data from up to 100 transmitters in a T24 network.